EMEC solenoid diaphragm dosing pumps VMS MF / Multifunction
Multifunction (constant or proportional, with pulse step-up/step-down, ppm, percent (%), batch, start-pause, 0-10 Volt, 0/4-20 mA)
for wall mounting
with microprocessor control and display
Dosing pump capacity adjustable in "ppm" [ mg/l ]
Stepless adjustment of stroke frequency 0÷180 Imp/min
Designed as a multifunction pump or with integrated pH or redox control
Version with timer function for biocide/algicide dosing
Dosing head, injection valve and foot valve made of PVDF, dosing hose made of PE
Alternatively dosing head and accessories made of PP with PE dosing hose
suitable for viscosities up to 100 cP
Model |
VMS-MF |
VMS-PO (PH) |
VMS-PO (RH) |
VMS-EN |
Dosage |
Multifunction (constant or proportional, with pulse step-up/step-down, ppm, percent (%), batch, start-pause, 0-10 Volt, 0/4-20 mA) |
Proportional to pH value0 ÷ 14 pH with dosing time limit (supplied without pH electrode) |
Proportional to redox potential 0 ÷ 1000 mVwith dosing time limit (supplied without pH electrode) |
With integrated timer function (min. / hour / day / week) |
Empty detector |
X |
X |
X |
X |
Stand-by input |
|
X |
X |
|
Relay output Alarm |
option |
option |
option |
for magnetic valve |
Accessories
injection valve 1/2" - hose connection 4x6 mm
Axial foot valve with empty signal level switch
and 2.5 m connection cable with BNC plug
2.5 m control cable RG174 with BNC connector
Microfuse 4 x 20 mm
2 fixing screws with 6 plugs
each 2 m dosing, suction and venting hose
Operating instructions
The device complies with the following EU standards: -Low Voltage Directive (2014/35/EU)-EMV Directive (2014/30/EC)-RoHS - Directive (2011/65/EU)-EN ISO 12100:2010-EN 809:1998 + A1:2009 + AC:2010-EN 61010-1:2010-EN 50581:2012-EN 61000-6-2:2005 + AC:2005-EN 61000-6-3:2007 + A1:2011 + AC:2012
Technical details EMEC dosing pumps series VMS
MODEL |
MF |
Digital multifunction pump |
PO |
Pump for measurement/control of pH (0÷14 pH)/redox potential (0÷1000 mV) |
EN |
Pump with integrated timer function |
Model VMS |
DOSING PERFORMANCE |
Ml PRO HUB |
CP* |
HOSE |
VALVE |
2001 |
1 l/h - 20bar |
0.1 |
J |
4 x 8 |
3/8" |
1802 |
2 l/h - 18bar |
0.19 |
K |
4 x 8 |
3/8" |
1804 |
4 l/h - 18bar |
0.37 |
K |
4 x 8 |
3/8" |
1502 |
2 l/h - 18bar |
0.19 |
K |
4 x 6 |
3/8" |
1504 |
4 l/h - 15bar |
0.37 |
K |
4 x 6 |
3/8" |
1505 |
5 l/h - 15bar |
0.46 |
K |
4 x 6 |
3/8" |
1001 |
1 l/h - 10bar |
0.10 |
J |
4 x 6 |
3/8" |
1004 |
4 l/h - 10bar |
0.37 |
K |
4 x 6 |
3/8" |
1005 |
5 l/h - 10bar |
0.46 |
K |
4 x 6 |
3/8" |
1010 |
10 l/h - 10bar |
0.93 |
K |
4 x 6 |
3/8" |
0706 |
6 l/h - 7bar |
0.56 |
K |
4 x 6 |
3/8" |
0510 |
10 l/h - 5bar |
0.93 |
K |
4 x 6 |
3/8" |
0512 |
12 l/h - 5bar |
1.11 |
K |
4 x 6 |
3/8" |
0501 |
1 l/h - 5bar |
0.1 |
J |
4 x 6 |
3/8" |
0408 |
8 l/h - 4bar |
0.74 |
K |
4 x 6 |
3/8" |
0310 |
10 l/h - 3bar |
0.93 |
K |
4 x 6 |
3/8" |
0215 |
15 l/h - 2bar |
1.38 |
K |
6 x 8 |
3/8" |
0116 |
16 l/h - 1bar |
1.48 |
K |
6 x 8 |
3/8" |
Operating conditionsMax. permissible viscosity: 100 cps Max. suction height: 1.5 m Storage and transport temperature: -10 ... +50° C
Operating and ambient temperature: -10 ... +45° C Permissible media temperature: +1 ... +40° C for PVDF, PP, PE and PVC
|
HYDRAULIC COMPONENTS |
Hoses |
Viscosity |
|
Dosing head |
O-rings |
Balls |
Membrane |
pressure side |
suction side |
max. CPS |
1 |
PVDF |
FKM B |
ceramic |
PTFE |
PE |
PVC |
100 |
3 |
PVDF |
EPDM |
4* |
PVDF |
FKM B |
5* |
PVDF |
EPDM |
V |
PP |
FKM B |
D |
PP |
EPDM |
W |
PP |
WAX (nitrile) |
ELECTRICAL DATA |
Model |
Pulse frequency |
Average power consumption at max. dosing capacity |
Impulse per hour |
Impulse per min. |
230 VAC |
Backup |
115 VAC |
Backup |
|
min. |
max. |
Watt |
A / mA |
Watt |
mA |
2001 |
1 |
180 |
16 |
1 |
13 |
500 |
1802 |
16 |
1 |
13 |
500 |
1804 |
22 |
1.25 |
15 |
630 |
1502 |
16 |
800 |
11 |
400 |
1504 |
16 |
1 |
13 |
500 |
1505 |
22 |
1.25 |
15 |
630 |
1001 |
16 |
800 |
11 |
400 |
1004 |
16 |
800 |
11 |
400 |
1005 |
16 |
1 |
13 |
500 |
1010 |
22 |
1.25 |
15 |
630 |
0706 |
16 |
800 |
11 |
400 |
0510 |
16 |
1 |
13 |
500 |
0512 |
22 |
1.25 |
15 |
630 |
0501 |
16 |
800 |
11 |
400 |
0408 |
16 |
800 |
11 |
400 |
0310 |
16 |
800 |
11 |
400 |
0215 |
22 |
1.25 |
15 |
630 |
0116 |
16 |
1 |
13 |
500 |
Supply voltage |
00 | 230 VAC Schuko plug |
0S | 230 VAC plug Australia |
01 | 230 VAC without plug |
03 | 115 VAC Plug US |
04 | 24 VAC without plug |
05 | 12 VDC* |
07 | 24 VDC |
operating instructions:
German
data sheet:
German